Section 45 of 55
92. System-Level Safety Architecture
Stable section ID: S05-CON-011-SECTION-45 · 25 content blocks
Every consequential robotic deployment shall define a System-Level Safety Architecture covering equipment, tasks, work zones, temporary structural states, human interaction, utilities, communications, and failure recovery.
The architecture should distinguish among:
- Inherently safe mechanical design.
- Operational control functions.
- Independent protective functions.
- Emergency functions.
- Human supervision.
- Administrative controls.
- Physical inspection and acceptance.
- Cybersecurity controls affecting physical safety.
Safety-related functions shall be sufficiently independent from ordinary optimization and production systems. Failure of a planner, AI model, fleet coordinator, Digital Twin, or cloud service shall not disable the protective functions necessary to prevent injury or uncontrolled physical action.
The architecture shall identify:
- Safety boundaries.
- Controlled entities.
- Hazardous energy sources.
- Safe and unsafe states.
- Required response times.
- Stopping and holding behavior.
- Redundancy and diagnostic coverage.
- Common-mode failure risks.
- Authority for reset and restart.
- Required inspection and testing.
- Interfaces with site emergency procedures.
System-level validation shall evaluate the actual robot–tool–payload–site configuration. Certification of an individual robot or tool shall not automatically establish the safety of the integrated operation.