Section 29 of 104
27. Minimum Cartridge Family
Stable section ID: S05-CON-016-SECTION-29 · 25 content blocks
The Minimum Cartridge Family shall provide the required adaptation between System05 Nodes and the initial Components, members, panels, utilities, or devices.
The initial family should include:
primary structural member-end Cartridges;
bracing or lateral-load Cartridges;
panel or enclosure attachment Cartridges;
utility-routing or protected-passage Cartridges;
blanking and protective Cartridges;
transition or test Cartridges;
Smart Module or sensor-access Cartridges where applicable.
Each Cartridge shall define:
compatible Node and Interface Versions;
compatible Component or material range;
load-transfer behavior;
alignment and tolerance requirements;
locking and release sequence;
inspection method;
failure and replacement behavior;
environmental and fire protection;
identity and traceability;
permitted installation tools;
human and robotic access requirements.
Cartridges should concentrate material-specific adaptation and replaceable complexity so that the Node platform can remain stable across multiple Product generations.
A Cartridge shall not conceal a critical connection state without an approved inspection or sensing method.
Cartridges that appear geometrically similar but have different capacities or functions shall remain distinguishable through physical features, identifiers, markings, and digital validation.
Replacement shall require compatibility checking and appropriate BIOS and Digital Twin updates.