Section 93 of 101
92. Cartridge Architecture Integration
Stable section ID: S05-CON-006-SECTION-93 · 47 content blocks
Every System05 Cartridge shall be integrated into the BIOS as a uniquely identified, replaceable, capability-bearing engineering asset.
The BIOS shall retrieve or store:
Cartridge Type and Instance identity;
Cartridge Digital Passport;
Cartridge classification;
manufacturer and version;
host-side and service-side Interfaces;
physical location;
installation orientation;
Capability Declaration;
operational requirements;
dependencies;
configuration;
firmware and software;
commissioning status;
lifecycle state;
maintenance requirements;
safety limitations.
Cartridge integration shall follow:
discovery;
authentication;
Registry comparison;
assigned-location verification;
Interface compatibility verification;
dependency validation;
capability negotiation;
commissioning;
permission assignment;
operational activation.
The BIOS shall distinguish between a Cartridge being:
physically present;
registered;
connected;
commissioned;
authorized;
operational.
Replacing a Cartridge shall trigger:
dependency analysis;
safe disconnection;
removal of the previous Instance from the active topology;
verification of the replacement;
configuration update;
recommissioning;
Digital Twin reconciliation;
lifecycle recording.
A replacement Cartridge may come from a different manufacturer if it satisfies the required Interface, capacity, Profile, certification, and lifecycle requirements.
The BIOS shall not permit a Smart or Control Cartridge to obtain broader authority than its declared and approved function.